Qfarm ChangeLog

CHANGES from 1.33 to 1.34 dated 03-07-2023
- Fixed NH3 representation in last 48 hours archives
- Filtered NH3 reading to inhibit NH3D probe initialisation
- Locked in (E->2->4->H...) access to nest times if set independent from LAB 


 CHANGES from 1.32 to 1.33 dated 26-01-2023
- Corrected calculation of M3h variation for CO2, NH3, T.External and Temporary Variation
- Changed lights datatype (advance/lag) from mm:ss to hh:mm:ss
- Modified nest datatype (early/late) limit from 300' to 720'
- New independent nests function
- New aux 1 and 2 timer function
- Improved external humid climate management (possibility to set a negative delta)
- Improved nest relay management (1" wait on relay exchange)
- Improved 0-10v ventilation forcing management (active only if set for a time ->0v*1"+10v*T) 


 CHANGES from 1.32 to 1.33 dated 26-01-2023
- Corrected calculation of M3h variation for CO2, NH3, T.External and Temporary Variation
- Changed lights datatype (advance/lag) from mm:ss to hh:mm:ss
- Modified nest datatype (early/late) limit from 300' to 720'
- New independent nests function
- New aux 1 and 2 timer function
- Improved external humid climate management (possibility to set a negative delta)
- Improved nest relay management (1" wait on relay exchange)
- Improved 0-10v ventilation forcing management (active only if set for a time ->0v*1"+10v*T) 


 CHANGES from 1.31 to 1.32 of 15-09-2022
-Fixed bug generated in 1.31 on the display of "Females", "Males" and "Feed" on the Home page 


 CHANGES from 1.30 to 1.31 12-09-2022

- Correction of "Gr / Head of programmed water" display in the "Feeding Details" screen in the case of water at will
- Added possibility of excluding ampere and pressure alarms and cooling function in case of natural ventilation (double ventilation)
- Removed display of spare parts countdown in case they are excluded
- Changed data type of "set_avaria_flaps" (limit to 5:00 ')
- Changed bootstrap value of "set_avaria_flaps" (from 5:00 'to 2:00')
- Improved "flap movement" alarm management  


 CHANGES from 1.29 to 1.30 12-05-2022

- Fixed "maximum ventilation% step" block signal
- Correct value at boot for general NO / NC alarm contact
- Fixed fan-jet timing
- Added "Excluded" setting for the item weighing alarm
- Improved weight management (awaits confirmation on important changes)
- Improved peripheral connection (failure alarm after 16 failures)
- Improved data transfer to PC (silos unloading)
 


CHANGES from 1.28 to 1.29 14-01-2021

 - Fixed total egg archive
- Added settings for general NO / NC alarm contact
- Limited minimum rotation settings to 1
- Improved data passage for cloud gateways 
AMENDMENTS from 1.27 to 1.28 of 29-06-2020
- Modified nest opening / closing setting from min: sec to whole minutes (up to 300 ')
- Ventilation diff setting limit changed from 0.0 ° -30.0 ° to 0.2 ° -1.0 °
- Modified value at bootstrap of delta T sampling time from 5:00 'to 1.00'
- Alarm bootstrap value changed in (E-1-8-9) from "Display" to "Enabled"
- Fixed echo response from remote write (Error introduced in 1.24)
- Corrected stop ventilation with "set_memoria_parzializzazione_m3h = No" in the case set "Maximum ventilation" at the maximum step - 1 (the problem occurs at start-up or in the event of temperature fanning)
- Corrected silos loading totals
- Correct amperometric alarm with set ventilation delay
- Fixed vision of flaps set from 9 to 16
- Fixed 0-10v name table length to load on first bootstrap (48 to 64)
- Added manual relay page to drive up to 119
- Added bootstrap alarm
- Added German
- Arab language embryo 


CHANGES from 1.26 to 1.27 09-04-2019 

- Correct light output 0-10v (with lux) in fasting
- Fixed "heads = 0" message if ventilation only
- Added "Minimum maintenance" (E-2-4) to keep lights out of hours (turkeys)
- Added "Maximum speed% block" and "Maximum block% step number" (E-1-3-3-2-H) to limit 0-10v ventilation (with ramp)
- Russian added


CHANGES from 1.25 to 1.26 26-09-2018 

- Modified operation of feeders for hens
- Improved cycle start with reset of any silos or medicated load in progress
- Correct ventilation rotation management (could rotate on a step greater than the set maximum)
- Correct password access management (showed an incomplete screen if you first accessed a locked setting - set calendar type)
- Amperometric alarm exclusion by setting "minimum absorption step x" to 0.0A
- Added warning "Attention: capi = 0"
- Added Portuguese 


 CHANGES from 1.24 to 1.25 16-03-2018

- Improved NH3 / CO2 exclusion management - display -1.0 / -1 in case of exclusion
- If select two LUX probes there are two 0-10v outputs and two independent minimum brightness alarms
- New management of feeders for hens
- Added lights relay off with reading lux> set + 1/2 dif and output = 0
- Added possibility of exclusion of 4-20mA humidity probes
- Modified value at boot of "Minimum brightness" 


 CHANGES from 1.23 to 1.24 18-01-2017

- Correct calculation 0-10v output lights during the descent ramp (with lights & lux)
- Improved 0-10v window management during air changes (timing) in m3 / h - (window is positioned at the set of the step calculated in ON and at the set of the previous step in OFF)
- Improved connection management with PC
- New possibility to assign the status of the "external alarm exclusion" contact to the optional alarm relays
- Added possibility of exclusion of CO2 / NH3 probes
- Added up mangers at the end of the fast
- Modified heating block delay time from 2 to 5 seconds
- Modified values at boot in Flap, Ventilation, Cooling, Alarms 


CHANGES from 1.22 to 1.23 12-10-2017
- New light output with output 0-10v according to the luminosity probe (Lux), with the possibility of having up to two brightness probes.
- New display screen for luminosity probes
- New minimum luminosity alarm
- Added Calendars / Activation / Maximum Limit for 0-10V Light Management with luminosity Probe (Lux)
- Added step view inserted in the new "Table Info"
- Added reset flap in case of motion alarm
- Added ventilation set recording in daily archives (net pro)
- Added possibility to exclude cooling block for too much humidity (setting 100%)
- Modified data-type asc. and des. manger - Limit range from 10 'to 99' (maximum value in min: sec)
- Modified Power Calendar Values (Ross 308 curve)
- Added controls for Qfarm Net PRO with www.qfarm.cloud service 


 CHANGES from 1.21 to 1.22 10-05-2017

- New light management (only reading probe 0-10v on the first HXDA)
- New NH3 management (0-10v probe on HXNE)
- New screens Operating Tables Ventilation / Flap (Home> H> H> C)

CHANGES from 1.20 to 1.21 27-03-2017

- Fixed calculating water consumption at the end of the medicated (Archive_Day -> Days_Cycle)
- Fixed viewers Management (conn) -> Error introduced in 1:19 after modification for use with Qstorage
- Modified boot value of "Cycle Time spare parts" (E-1-3-2-1) to 600 "(10 ') to 300" (5') 


CHANGES from 1.19 to 1.20 07-02-2017

- Fixed malfunctioning heating on/off in case of fan-jet enabling 0-10v
- Modified date-type "Display brightness" (E.2.4.D.3) (from +/- 80% to +/- 99%)
- Improved loading times by tables (erase)
- Added French language 


CHANGES from 1.18 to 1.19 25-01-2017

- Updated RTC management to manage new CPU
- Updated spi-flash library to manage new chip 


CHANGES from 1.17 to 1.18 29-09-2016

- Limited write eeprom remotely (only possible in the minimum / maximum range)
- Calculation using PC
- Improved read keyboard handling
- Updated USB host library - MSC
- Updated file system 


CHANGES from 1.16 to 1.17 20-07-2016

- Increase the buffer size for USB handling filenames
- Improved management of external EEPROM (new chip Clock <10Mhz)
- Theoretical weight calculation feed curve to be used by PC 


CHANGES from 1.15 to 1.16 24-05-2016

- Fixed EG GUI data type (signed)
- Improved schedules limit filter (related to the problem above) 


CHANGES from 1.14 to 1.15 05-05-2016

- Fixed wrong access to the distribution screen if Qfarm ventilation only
- Fixed record date of the pre-boot cycle
- Fixed daily recording time igniting lights (was not saved at midnight)
- Fixed operating times power representation (problem if> 23:59)
- Fixed medicated delay minimum level sensor intervention
- Fixed zero external flash sectors to boot cycle (in the archives were correct only the first 255 days of the cycle)
- Fixed associative flap operation in air changes (minimum ventilation) in M3H and 0-10v
- Fixed CO2 graph
- New insight into the ventilation screen (countdown on and off of the air changes also M3h)

 

 

Handbook request

Performance comparison Xfarm vs Qfarm

 
Xfarm
Qfarm
 
 xfarm frontale th
qfarm frontale th 
 
   
Color Display
ico stato vero
ico stato vero
Display specifications
4.3” 480x272
7” 800x480
 
   
N° ventilation steps
10
16
N° flaps
2
16
N° heatings
3
16
Fanject - destratifiers
ico stato falso
ico stato vero
Radiant heatings
ico stato falso
ico stato vero
N° coolings
1
2
Humidification ico stato falso ico stato vero
Amperometric alarm ico stato falso ico stato vero
M3/h ventilation ico stato falso ico stato vero
Double climate ventilation (Climate A, B) ico stato falso ico stato vero
Heat index ico stato falso ico stato vero
Climate calendar curves ico stato vero ico stato vero
Feeding calendar curves ico stato falso ico stato vero
Lights control (number) 1 8
Water measurement (number of counters) 1 2
Birds-weighing 1 2
Silo-weighing 1 3
Total inputs available 24 112
Total outputs On-Off available 30 105
Total outputs 0-10v  available 4 46
Data management with USB support
ico stato vero ico stato vero
Configuring system parameters
on board by PC
Network connection to PC (supervisor) ico stato vero ico stato vero

Xfarm Display Emulator

 PC software to displaying Xfarm screens, can also choose the language.

xfarm demo

Available in download area

COUNCIL DIRECTIVE 2007/43/EC

ico euro bookCOUNCIL DIRECTIVE 2007/43/EC of 28 June 2007 laying down minimum rules for the protection of chickens kept for meat production.

 

 

Choice HP module format

The modules of the HP line are available in two formats

panel version

 

wall version

pan HP75
Example
module
HP75
 pan HP75
 HP75
 
 HP75/W
The version /W is the perfect solution for direct application to the wall or on the machine to be controlled.
All models are available in panel version (DIN96) or in  IP54 (/W) version.
Example: if you want to order a HP75 wall version the cose is HP75/W (HP75 identifies the panel version DIN96)
 
Recommended options for the panel version:
 
ghp foto  ct foto

Company profile

extpola

POLA s.r.l.  Via Del Perolo n° 13  26029 SONCINO (CR) ITALY

 

HUMAN RESOURCES

humOur company has been developing automation systems since 1978 and now it can boast a highly skilled team of engineers for studying and developing the product right from the initial design stage to its final application. The experience acquired is intensively put into practice at all manufacturing stages to guarantee equipment performance and commitment to customer support. Close cooperation between R&D and production is essential to get the best from technical equipment design and application.
 
 

INDUSTRIAL PLANT

prod1Our production departments are fully automated to efficiently meet the various customers' requirements and guarantee proved standards with reduction of costs, which so far was only possible on a large-scale production.

prod1

Our equipment is designed in strict compliance with the applicable local and major international safety standards and each part is accurately tested to ensure top performance and full reliability.

 

TECHNOLOGICAL PROGRESS

techprogAdvanced hardware design is the bedrock of our success with an intensive use of computer-based process automation systems right from the second half of the eighties, even in applicative fields which were considered “too poor” for computer science application.
POLA can now boast thousands of processors installed in agricultural industries and homes throughout the world, working in different climate conditions.
 

 CUSTOMER SUPPORT

office2The range of products includes a few hundreds of standard models destined to various fields of process automation.
Customized systems can also be committed to our research team that is able to develop specific high-tech products within a space of time as short as a week.

 

ACCOUNTING

office1A data processing centre (EDP) linked in real time to internal user video terminals provides immediate handling of orders to ensure prompt deliveries.
 
   MARKETING

office3Development of new products presupposes in-depth knowledge of the market situation and target range.
This is why we take special care in selecting the appropriate media to back up our product sales with advertisements in top trade magazines.

New Qfarm v1.34 software version

 

ico new box blu

New Qfarm v1.34 software version

It 'was recently made available the new version of the Qfarm software v1.34 with new features and improved graphics!

Aggiornamento Qfarm x Mail 127 ENG

If your Qfarm is not update you can request the update for free through the link below.

 

 


Keep updated your Qfarm

ico internet  freccia dxico usb  freccia dx  qfarm frontale th

 
 

The service is completely free of charge, once registered with every release of a new release you will automatically receive an email.

If you are not yet registered to the update service you can do by filling out the form on this page:
This email address is being protected from spambots. You need JavaScript enabled to view it.